TL-2800ASX

Ammonia & Nitrate/Nitrite Analyzer

A Superior Analytical Method

Achieves Superior Performance

  • Fast Analysis

    – From 1.5 to 2.5 Min/sample

  • Very Few Interferences

    – Immune to sample color variation
    – Turbidity tolerant – very little or no sample filtering required

  • Automated

    – Setup external samples, load samples and let it run

  • Wide Dynamic Range

    – Standard 50 ppb to 500ppm
    – High Sensitivity – 10 ppb to 10 ppm

  • Low Cost of Maintenance and Operation

    – Annual maintenance costs are less than half of competitive methods
    – At 50 samples/day the cost per sample is about 10
    ¢

  • No Distillation Required

    – TKN and TN can be determined directly after digestion. Just run the sample

  • Not Just Ammonia

    – The TL-2800A/TL-2800TIN ASX pair provide direct NH3, TIN and indirect Nitrate/Nitrite analysis

  • EPA Approved

    – CFR 40 Part 136 Listed and wastewater approved under Clean Water Act Applications

  • Easy and Safe – No Cadmium

    – Simple to make and inexpensive Reagents
    – Non-toxic Reagents and Non-toxic Wastes

Request a quotation for a TL-2800 ASX Analyzer System

TL-2800 ASX Products

TL-2800A ASX – Ammonia analyzer

TL-2800N ASX – TIN analyzer

TL-2800A ASX and TL-2800TIN ASX Paired

Convenient On-board Storage Space

More on the TL-2800 ASX Ammonia & TIN Analysis Systems

Specifications

TL-2800A ASX Ammonia Analyzer

 

Physical    

Length 18.1 Inches (460 mm)
Width 9.5 Inches 241 mm)
Height  7.5 Inches (190 mm)
Weight 9 pounds (4 Kg)

 

 

Electrical    

 
Power Voltage 120/240 VAC 50/60Hz
Wattage (min) 150 W
   
   

 

 

Performance

TL-2800A ASX

 
Analysis Time

1.5 to 2.5 Minutes

Standard Dynamic Range 50 ppb – 500 ppm
High Sensitivity Dynamic Range 10 ppb to 10 ppm
Precision  1% of reading
Accuracy   +/- 5% NH3
Calibration Frequency Daily
Calibration Single or Multipoint

Specifications

TL-2800A ASX – Ammonia Analyzer &

TL-2800TIN ASX – Total Inorganic Nitrogen Analyzer

 

Physical    

 
Length 18.1 Inches (460 mm)
Width 19.5 Inches 495 mm)
Height  7.5 Inches (190 mm)
Weight 9 pounds (4 Kg)

 

 

Electrical    

 
Power Voltage 120/240 VAC 50/60Hz
Wattage (min) 150 W
   
   

 

 

Performance

TL-2800A+TIN ASX

 
Analysis Time 1.5 to 2.5 Minutes
Standard Dynamic Range 50 ppb – 500 ppm
High Sensitivity Dynamic Range 10 ppb to 10 ppm
Precision  1% of reading
Accuracy   +/- 5% NH3 and +/- 5% TIN (+/- 10% Nitrate/Nitrite)
Calibration Frequency Daily
Calibration Single or Multipoint